Page view 56
– 57 –
Testing The System (cont’d)
Testing Your System
1. Open and close each protected door and window in turn and listen
for three beeps. The identification of each faulted protection point
should appear on the display.
2. Walk in front of any interior motion detectors (if used) and listen
for three beeps as movement is detected. The identification of the
detector should appear on the display when it is activated.
3. Follow the manufacturer's instructions to test all smoke detectors
to ensure that all are functioning properly. The identification of
each detector (or the zone number of the zone assigned to the
detector) should appear on the display when each is activated.
4. When all protection points have been checked, there should be no
zone identification numbers displayed. If a problem is experienced
with any protection point (no confirming sounds, no display),
CALL FOR SERVICE IMMEDIATELY.
5. Turn off Test mode by entering the security code and pressing the
OFF key.