0150-0296A 78 Vista Columbus Triplex CDR
8.3 Alarm/Event Fields
The two least significant bits are currently used for the Event commands. Bits 2 and 3 are used for the
Alarm commands.
7 6 5 4 3 2 1 0
MSB
LSB
Event Start
Event Stop
Alarm Start
Alarm Stop
8.4 Alarm Actions
No Alarm Change 0000 00XXb
If both the start and stop bits are clear, the alarm status and camera record rates will remain
unchanged.
Start Alarm 0000 01XXb
If only the start bit is set, the Vista Columbus Triplex CDR will enter the Alarm mode. The selected
camera will become the alarm camera. Pre-alarm video will be recorded and the Alarm Record Rate
will be initiated.
Every Start Alarm command should subsequently be followed with a Stop Alarm command
at some point. Failure to do so will render that alarm input useless, even if the alarm was
latched and gets acknowledged from the front panel. A Stop Alarm followed by a Start Alarm
will have to be sent to create a new alarm on that channel.
Stop Alarm 0000 10XXb
If only the stop bit is set, the selected camera’s alarm status will be cleared. If no other alarms are
present, the Vista Columbus Triplex CDR will exit the alarm mode.
Momentary Alarm 0000 11XXb
If both the start and stop bits are set, a momentary alarm will be initiated on the selected camera. Pre-
alarm video will be recorded at the alarm record rate, after which the Vista Columbus Triplex CDR will
continue to record video at the normal record rate.
NOTE